Site review · RTX PRO 6000 Max only
Check the home first.
Use this checklist with the homeowner and installer before promising eligibility or installation scope. Final approval requires the vendor's site review.
| Item | Specification or planning basis |
|---|---|
| Compute | 1 × NVIDIA RTX PRO 6000 Blackwell Max-Q Workstation Edition; 96 GB GDDR7 ECC; 300 W GPU board power. |
| CPU / memory / storage | AMD Ryzen 9 9950X, 16 cores / 32 threads; 128 GB DDR5; 6 TB NVMe (2 TB system + 4 TB workload). |
| Cooling / software | Air cooling throughout; no water cooling. Ubuntu Server and compatible NVIDIA drivers, managed by Vendor. |
| Approximate envelope | 800 W × 400 H × 220 D mm (31.5 × 15.7 × 8.7 in), excluding mounting rail, cable and service clearance. |
| Estimated weight | 34 lb (15.6 kg) node; 37 lb (16.6 kg) installed with rail. This is not a bracket capacity rating. |
Location & installation
- Dry, climate-controlled indoor location confirmed. A garage qualifies only if climate controlled.
- Wall anchors reach suitable studs or framing. Drywall-only attachment is insufficient; bracket design must suit measured assembly weight.
- Intake, exhaust, GPU cable bends and service access checked. Final clearances must be confirmed by the installer.
- Grounded 120 V / 60 Hz outlet and sustained circuit capacity verified with other loads. Flexible mains cords remain outside walls.
- Location and Ethernet route marked at survey. New wiring, sub-panel or extended runs are separately assessed scope.
Internet & activation
- Service rated at least 1 Gbps download and 1 Gbps upload documented. A download-only gigabit plan is insufficient.
- Wired Ethernet reaches the node; router, ports and cable route are suitable.
- Vendor verifies service limits, compute-hosting permission and provider acceptance. Public-IP / port needs checked separately.
- Any required ISP upgrade and extra monthly cost reviewed before commitment.
- Host authority, reasonable service access and vendor acceptance recorded. Activation follows installation, commissioning and acceptance; it does not require a first paid workload.
Power: use the right number
| Scenario | Whole-node outlet estimate | Energy if continuous |
|---|---|---|
| Idle / low activity | 80-130 W | 58-94 kWh / 30-day month |
| Workload | 400-550 W | 288-396 kWh / 30-day month |
| Planning allowance | 700 W sustained; not tested max | 504 kWh / 30-day month |
300 W is GPU board power. 1,000 W is PSU capacity, not node draw. Size, weight and power are preliminary estimates pending final assembly validation. Air-cooled CPU limits and sustained temperatures need validation; additional household cooling electricity is extra.
Proposed location / Ethernet route
ISP download / upload; circuit review
Additional scope / unresolved items
Reviewer / review date / vendor acceptance